1. ABOUT THE DATASET -------------------- Title: Data Associated with 'Injection Volume Is a Better Predictor of Stiffness Restoration Than Injection Force in an In Vitro Study of Nucleus Augmentation of the Intervertebral Disc' Creator(s): Warren JP [1], Mengoni M [1], Wilcox RK [1]. Organisation(s): 1. University of Leeds. Rights-holder(s):Unless otherwise stated, Copyright 2025 University of Leeds Publication Year: 2025 Description: Data from a biomechanical study of spinal nucleus augmentation with a self-assembling hydrogel. The biomechanical data was acquired during in vitro testing of bovine tail specimens in a native, artificially degenerated, and treated states. Cite as: Warren JP, Mengoni M, Wilcox RK. 2025. Data Associated with Injection Volume Is a Better Predictor of Stiffness Restoration Than Injection Force in an In Vitro Study of Nucleus Augmentation of the Intervertebral Disc. [Dataset] https://doi.org/10.5518/1712 Related publication: Warren JP, Dixon AR, Culbert MP, Khan A, Mengoni M, Wilcox RK. Injection Volume Is a Better Predictor of Stiffness Restoration Than Injection Force in an In Vitro Study of Nucleus Augmentation of the Intervertebral Disc. JOR Spine. 2025 Jun 10;8(2):e70081. doi: 10.1002/jsp2.70081. PMID: 40496969; PMCID: PMC12149600. Contact: r.k.wilcox@leeds.ac.uk 2. TERMS OF USE --------------- Copyright 2025, University of Leeds. Unless otherwise stated, this dataset is licensed under a Creative Commons Attribution 4.0 International Licence: https://creativecommons.org/licenses/by/4.0/.] 3. PROJECT AND FUNDING INFORMATION ---------------------------------- Title: Unuversity of Leeds DTP Dates: 2018-2023 Funding organisation: EPSRC (Engineerng and Physical Sciences Research Council UK) Grant no.: EP/R513258/1 4. CONTENTS ----------- File listing SummaryData.csv This contains the core processed biomechanical data, used in the results presented in Figure 2b, Figure 4, Table 1 and in the text of the publication. Figure1.tiff A high resolution version of Figure 1 Figure2a_ExampleDataset.csv Typical stiffness data acquired over 1000 cycles in each of the three stages of testing. This data was used for Figure 2a. Figure2c_ExampleDataset.csv Typical force-time data acquired during the nucleus injection process. This data was used for Figure 2c. Figure3_***.PNG High resolution versions of each of the CT slices shown in Figure 3. Folder: Injection force time data T0**_D*_Injection.csv Force time data taken during the injection of each specimen 5. METHODS ---------- The detailed methods are provided in the associated publication.